7.3.3.8 no spanning-tree l2t-edge
Description
With this command, you disable the setting that an end device may be located at a layer 2
tunnel port.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree l2t-edge
Result
The setting is disabled.
Further notes
The automatic discovery of a bridge on the interface is disabled with the spanning-tree
l2t-edge command.
You can display the status of this function with the show spanning-tree l2t-
edgecommand.
7.3.3.9 spanning-tree mst configuration
Description
With this command, you change to the MSTP configuration mode.
Requirement
MSTP is enabled
Compatibility mode: MSTP
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 315

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals