Syntax
Call up the command with the following parameters:
show events faults config [{power|link}]
The parameters have the following meaning:
Parameter Description
power Monitoring of the power supply for power outage.
link Monitoring of the network connections for a change in the connection sta‐
tus.
If no parameters are specified, the settings for both error monitoring functions are displayed.
Result
The current configuration of the selected error monitoring function is displayed.
12.1.1.5 show events faults status
Description
This command shows the status messages of fault monitoring of the power supply and network
connections.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show events faults status
Result
A table with the status messages of the error monitoring functions is displayed.
12.1.1.6 show fault counter
Description
This command shows the number of fault transitions of the power supply and network
connections.
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
584 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals