9. Select the interface and click the "OK" button" button.
10.To start the recording click "Start". You can obtain further information about handling the
program in Wireshark.
If you analyze several interfaces you can use a Wireshark instance for each interface.
Further notes
You display this setting and other information with the show remote capture command.
You disable the function with the no capture command.
5.10.3.4 no capture
Description
With this command, you disable the "remote capture" function.
Requirement
You are in the REMOTE CAPTURE configuration mode.
The command prompt is as follows:
cli(remote-capture)#
Syntax
Call the command without parameter assignment:
no capture
Result
The function is disabled.
Functions specific to SCALANCE
5.10 Remote capture
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 165