8.6.2.13 no snmp group
Description
With this command, you delete the details of an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp group <GroupName> user <UserName> security-model {v1|v2c|v3}
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group max. 32 characters
user Keyword for the user name -
UserName Name of the user max. 32 characters
security-model Specifies which security settings are
used for sending.
v1
v2c
v3
Result
The details of the group are deleted.
Further notes
You change the details of an SNMP group with the snmp group command.
You display the created SNMP groups with the show snmp group command.
You display the created SNMP users with the show snmp user command.
8.6.2.14 snmp notify
Description
With this command, you configure the details of the SNMP notifications.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
424 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals