Result
The role is deleted.
Further notes
You create a role with the role command.
You show the created roles with the show roles command.
11.1.4.3 user-account
Description
With this command, you specify a new user. You can also change the password / role /
description of an already created user.
When you create a local user an entry is generated automatically in the table "External User
Accounts".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
user-account <user-name> password <user-password> role <user-role>
[description <user-description>]
The parameters have the following meaning:
Parameter Description Range of values / note
user-name User name Enter the name for the user. The name
must meet the following conditions:
It must be unique.
It must be between 1 and 250
characters long.
The following characters must not be
included: § ? " ; :
The characters for Space and Delete
must also not be included.
password Keyword for a password -
Security and authentication
11.1 User rights management
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 479

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals