cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree {cost <0-200000000>|disable|
link-type{point-to-point|shared}|portfast|
port-priority<0-240>}
The parameters have the following meaning:
Parameter Description Range of values / note
cost Keyword
Describes the costs of the port for cal‐
culating the lowest cost path.
0 ... 200000000
Default:
if dynamic calculation of the path
costs is not enabled:
200000 for physical interfaces
199999 for port channels
disable disables the interface for spanning tree -
Default:
The spanning tree function is ena‐
bled on the interface
link-type Connection status of the following net‐
work segment
point-to-point
shared
Default:
point-to-point
The connection is configured
as full-duplex
shared
in all other cases
portfast Enables the PortFast function -
Default: disabled
port-priority Priority of the interface 0 ... 240 in steps of 16
Default: 128
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 325

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals