Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3 {auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
ParamName Name of the SNMP parameter max. 32 characters
user Keyword for the user name -
UserName Value for the user name max. 32 characters
security-model Specifies which SNMP version is used.
With SNMPv3 a security level (authen‐
tication, encryption) can also be config‐
ured.
SNMP version
v1
v2c
v3
Security level for v3
auth
Authentication enabled / no
encryption enabled
noauth
No authentication enabled,
no encryption enabled
priv
Authentication enabled /
encryption enabled
message-
processing
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
SNMP version
v1
v2c
v3
Settings after the restart
:
The settings are lost after a
restart
:
The settings are retained
after a restart
Keywords need to be specified.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 429

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals