Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
mac-address-table aging-time <seconds(10-1000000)>
The parameter has the following meaning:
Parameter Description Range of values / note
seconds Life of the entry in seconds 10 ... 1000000
At system start or when using the restart command with the option memoryor factory,
the following defaults apply:
The default value is 300 seconds.
Result
The value of the aging of a dynamically learned entry is configured.
Further notes
You can reset the setting to the default with the no mac-address-table aging-time
command.
You display the setting with the show mac-address-table aging-time command.
Load control
9.1 Dynamic MAC aging
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 453