There are two options for replacing the device:
Option 1: The machine manufacturer only knows the serial number of the new inverter
The end customer provides the machine manufacturer with the following information:
For which machine must the inverter be replaced?
What is the serial number (r7758) of the new inverter?
The machine manufacturer goes online on the sample machine.
deactivates the know-how protection, see Settings for the know-how protection
(Page 338)
enters the serial number of the new inverter in p7759
enters the serial number of the inserted memory card as reference serial number in
p7769
activates the know-how protection with copy protection ("Copy RAM to ROM" must be
activated!), see Settings for the know-how protection (Page 338)
writes the configuration with p0971 = 1 to the memory card
sends the memory card to the end customer
The end customer inserts the memory card and switches on the inverter.
When powering up, the inverter checks the serial numbers of the card and when there is a
match, the inverter goes into the "ready to start" state.
If the numbers do not match, then the inverter signals fault F13100 (no valid memory card).
Option 2: The machine manufacturer knows the serial number of the new inverter and the
serial number of the memory card
The end customer provides the machine manufacturer with the following information:
For which machine must the inverter be replaced?
What is the serial number (r7758) of the new inverter?
What is the serial number of the memory card?
The machine manufacturer goes online on the sample machine.
deactivates the know-how protection, see Settings for the know-how protection
(Page 338)
enters the serial number of the new inverter in p7759
enters the serial number of the customer's memory card as reference serial number in
p7769
activates the know-how protection with copy protection ("Copy RAM to ROM" must be
activated!), see Settings for the know-how protection (Page 338)
writes the configuration with p0971 = 1 to the memory card