Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
386 Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
Table 12- 14 PM230, IP55, Frame Sizes A, 3 AC 380 V … 480 V
Order No. - Filtered, Class A
Order No. - Filtered, Class B
6SL3223-…
6SL3223-…
…0DE23-0AA0
…0DE23-0BA0
Rated / Low Overlaod values
Rated / LO power
Rated / LO input current
Rated / LO Output current
3 kW
8,0 A
7,7 A
High Overload values
HO power
HO input current
HO output current
2,2 kW
6,1 A
5,9 A
Fuse according to IEC
Fuse according to UL
3NA3803
10 A, class J
Power losses
0.12 kW
Required cooling air flow
7 l/s
Cross section of line and motor cable 1 … 2.5 mm
2
1814 AWG
Tightening torque for line and motor cable
0.5 Nm / 4.4 lbf in
Weight
4.3 kg
Table 12- 15 PM230, IP55, Frame Sizes B, 3 AC 380 V … 480 V
Order No. - Filtered, Class A
Order No. - Filtered, Class B
6SL3223-…
6SL3223-…
…0DE24-0AA0
…0DE24-0BA0
…0DE25-5AA0
…0DE25-5BA0
…0DE27-5AA0
…0DE27-5BA0
Rated / LO power
Rated / LO input current
Rated / LO Output current
4 kW
10.5 A
10.2 A
5.5 kW
13.6 A
13.2 A
7.5 kW
18.6 A
18 A
HO power
HO input current
HO output current
3 kW
8.0 A
7.7 A
4 kW
10.5 A
10.2 A
5.5 kW
13.6 A
13.2 A
Fuse according to IEC
Fuse according to UL
3NA3805
16 A, class J
3NA3807
25 A, class J
3NA3810
35 A, class J
Power losses
0.14 kW
0.18 kW
0.24 kW
Required cooling air flow
9 l/s
9 l/s
9 l/s
Cross section of line and motor cable 2.56 mm
2
1410 AWG
4 … 6 mm
2
1210 AWG
4 … 6 mm
2
1210 AWG
Tightening torque for line and motor cable
0.5 Nm / 4.4 lbf in
0.5 Nm / 4.4 lbf in
0.5 Nm / 4.4 lbf in
Weight
6.3 kg
6.3 kg
6.3 kg