Technical data
12.2 Technical data, Power Modules
Inverter with CU230P-2 Control Units
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
387
Table 12- 16 PM230, IP55, Frame Sizes C, 3 AC 380 V … 480 V
Order No. - Filtered, Class A
Order No. - Filtered, Class B
Rated / Low Overlaod values
Rated / LO power
Rated / LO input current
Rated / LO Output current
11 kW
26,9 A
15 kW
33,1 A
18.5 kW
39,2 A
HO power
HO input current
7,5 kW
18,6 A
11 kW
26,9 A
15 kW
33,1 A
Fuse according to IEC
3NA3814
3NA3820
3NA3820
Required cooling air flow
Cross section of line and motor cable 6 … 16 mm
2
10 … 16 mm
2
10 … 16 mm
2
Tightening torque for line and motor cable
Table 12- 17 PM230, IP55, Frame Sizes D, 3 AC 380 V … 480 V
Order No. - Filtered, Class A
Order No. - Filtered, Class B
Rated / LO power
Rated / LO input current
Rated / LO Output current
18.5 kW
39.2 A
38 A
22 kW
42 A
45 A
30 kW
56 A
60 A
HO power
HO input current
15 kW
33.1 A
18.5 kW
36 A
22 kW
42 A
Fuse according to IEC
3NA3820
3NA3822
3NA3824
Required cooling air flow
Cross section of line and motor cable 10 … 35 mm
2
16 … 35 mm
2
16 … 35 mm
2
Tightening torque for line and motor cable