Table 12- 26 PM240, IP20, frame sizes F, 3 AC 380 V … 480 V
Order No. - without filter
Order No. - with filter
Rated/LO power
Rated/LO input current
55 kW
129 A
75 kW
168 A
90 kW
204 A
HO power
HO input current
45 kW
108 A
55 kW
132 A
75 kW
169 A
Fuse according to UL (from SIEMENS)
Fuse according to UL (Class J)
3NE1224-0
3NE1225-0
3NE1227-0
Power losses without filter
1.4 kW
1.9 kW
2.3 kW
Required cooling air flow
Cross section of line and motor cables 35 … 120 mm
2
70 … 120 mm
2
95 … 120 mm
2
Tightening torque for line and motor cables
Weight without filter
36 kg
36 kg
36 kg
Table 12- 27 PM240, IP20, frame sizes F, 3 AC 380 V … 480 V
Order No. - without filter
Rated/LO power
Rated/LO input current
Rated/LO output current
110 kW
234 A
205 A
132 kW
284 A
250 A
HO power
HO input current
90 kW
205 A
110 kW
235 A
Fuse according to UL (from SIEMENS)
3NE1227-0
3NE1230-0
Required cooling air flow
Cross section of line and motor cables 95 … 120 mm
2
95 … 120 mm
2
Tightening torque for line and motor cables