Table 4- 3 Dimensions and clearances for the PM240
Frame size
Dimensions (mm)
Clearances (mm)
Height
1)
Width
Depth
4)
a
b
c
top
bottom
lateral
FSA
173
73
145
160
36.5
--
100
100
30
2)
FSB
270
153
165
258
133
--
100
100
40
2)
FSC
355
140
165
343
120
6
80
100
50
2)
FSD without filter
419
275
204
325
235
11
300
300
0
3)
FSD with filter
512
275
204
419
235
11
300
300
0
3)
FSE without filter
499
275
204
405
235
11
300
300
0
3)
FSE with filter
635
275
204
541
235
11
300
300
0
3)
FSF without filter
634
350
316
598
300
11
350
350
0
3)
FSF with filter
934
350
316
899
300
11
350
350
0
3)
FSGX
1533
326
547
1506
125
14.5
250
150
50
1)
Additional height with shield connection kit: FSA: +84 mm; FSB: +85 mm; FSC: +89 mm; FSD…FSF: +123 mm
2)
You can mount the Power Modules without any lateral clearance up to an ambient temperature of 40 °C in operation.
For tolerance reasons, we recommend a lateral clearance of approx. 1 mm.
3)
You can mount the Power Modules without any lateral clearance. For tolerance reasons, we recommend a lateral
clearance of approx. 1 mm.
4)
Total depth of the inverter: See below.
Table 4- 4 Mounting hardware for PM240
Frame size
Material
Tightening torque
FSA, FSB
M4 screws
2.5 Nm
FSC
M5 screws
2.5 Nm
FSD, FSE
M6 screws
6 Nm
FSF, FSGX
M8 screws
13 Nm
Table 4- 5 Dimensions and clearances for PM250
Frame size
Dimensions (mm)
Clearances (mm)
Height
1)
Width
Depth
4)
a
b
c
top
bottom
lateral
FSC
355
140
165
343
120
6
80
100
50
2)
FSD without filter
419
275
204
325
235
11
300
300
0
3)
FSD with filter
512
275
204
419
235
11
300
300
0
3)
FSE without filter 499 275 204 405 235 11 300 300 0
3)
FSE with filter
635
275
204
541
235
11
300
300
0
3)
FSF without filter
634
350
316
598
300
11
350
350
0
3)
FSF with filter
934
350
316
899
300
11
350
350
0
3)
1)
Additional height with shield connection kit: FSC: +89 mm; FSD…FSF: +123 mm
2)
You can mount the Power Modules without any lateral clearance up to an ambient temperature of 40 °C in operation.
For tolerance reasons, we recommend a lateral clearance of approx. 1 mm.
3
)
You can mount the Power Modules without any lateral clearance. For tolerance reasons, we recommend a lateral
clearance of approx. 1 mm.
4)
Total depth of the inverter: See below.