Operation 4
Display messages
Traction motor and pump motor monitoring
1 "Temperature of the right-hand traction
motor"
The maximum surface temperatu
re of
the right-hand traction motor
has been
reached.
No driving functions are available.
2 "Temperature of the left-hand traction
motor"
The maximum surface tempera
ture of
theleft-handtractionmoto
r has been
reached.
No driving functions are available.
3 "Pump motor temperature"
The maximum surface tempe
rature of
the pump motor has been rea
ched.
No driving functions are available.
Set down the load.
Actuate the reset button a
nd drive the truck
out of the potentially exp
losive area.
Safely bring the truck to a standstill.
Allow the overheated motor to cool down.
If one of the warning lig
hts (1-3) remains
illuminated after the m
otor has cooled
down, notify the author
ised service centre.
NOTE
The explosion-protection light "insulation
warning" (4) is not present in category 3 trucks.
Insulation monitoring
4 "Insulation warning"
There is an insulation fault.
No driving functions are available.
Switch off the truck immediately.
If necessary, perform emergency lowering
of the load and set down the load.
Tow the truck out of the potentially explosive
area.
See the section entitled "Towing" in the
chapter entitled "Operating in special
operating situations".