1 Foreword
Using the truck
Place of use
DANGER
There is a risk of explosion during use
in potentially explosive areas.
The truck may only be operated in the
potentially explosive areas for which it
is approved!
– Check the area of application by
comparing it with the nameplate
information.
– If the area of application is not clear,
ask the safety officer.
DANGER
Risk of explosion when brushing against equip-
ment!
If conductive components of the truck come into
contact with flexible doors or strip curtains, danger-
ous electrostatic charges can form.
– Avoid electrostatic charges.
DANGER
Risk of explosion when using without conductive
flooring!
The truck must only be operated in potentially
explosive areas that are fitted with conductive
flooring.
– Avoid electrostatic charges.
NOTE
More information concerning the require-
ments for conductive or dissipative floorings
can be found in the guidelines relating to elec-
trostatic hazards "CLC/TR 60079-32-1".
The tr
uck is approved in accordance with
Direc
tive 2014/34/EU for use in potentially
explo
sive areas. These areas are specified
on the
nameplate. In such areas, the safety
office
r must approve access by the truck.
Relatio
nship between zones and equipment
categor
ies for industrial trucks
• Zone 1 – category 2G
Use is permitted in areas where hazardous,
potentially explosive atmospheres may
24 5
6368011531 EN - 06/2019 - 02