Maintenance 5
Preserving operational readiness
The protected areas are identified with
the decal information "ELECTRICALLY
CONDUCTIVE".
Non-coated areas are labelled as follows:
"Non-conductive parts - risk o
f electrostatic
charge - only clean using a damp
cloth"
The surface resistance must be less than
or equal to 1 GΩ (10
9
Ω) at a test voltage of
500 V
Any damage to the paint layer must not
exceed a specified surface area.
Refer to the table below!
For repairs, it is absolutely essential to use
antistatic paint made by the same manufac-
turer and with the same specifications.
Maximum permissible dama
ge to the surfaces
Category of the truck
Maximum permissible
damaged area
IIA
IIB
100 cm
2
IIB + H
2
IIB + C
2
H
2
IIB + H
2
+C
2
H
2
20 cm
2
Please contact your authorised service
centre for repair or advice if you have any
questions.