Safety 2
Safety tests
The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batte-
ries must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal voltage
U
Batt
Test values
50 VDC 24 volts > 1200
100 VDC 48 volts > 2400
Battery
100 VDC
Batt+
Batt-
Battery tray
80 volts > 4000
.
Test values for the entire truck
Nominal voltage Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 volts 50 VDC Min. 50 kΩ > 24 kΩ
48 volts 100 VDC Min. 100 kΩ > 48 kΩ
80 volts 100 VDC Min. 200 kΩ > 80 kΩ
.
563
68011531 EN - 06/2019 - 02 61

Table of Contents