Description Of Specific Functions 139
V560 Series High Performance Closed-Loop Vector Inverter User Manual
Table 7-9 Contrast table of process PID feedback switching status
Terminal status Process PID feedback of frequency inverter
ON Process PID feedback 2
OFF Process PID feedback 1
33: Process PID sleep activation
When the sleep function is activated by multifunctional input terminals (set F7.2.34 as 2), the functional
terminal can activate process PID sleep function.
34: Torque/speed control mode switching
The functional terminal is applied to switch closed loop control mode of frequency inverter between torque
control and speed control. See the closed loop control mode of frequency inverter as following table:
Table 7-10 contrast table of closed loop control mode of frequency inverter
Terminal status Closed loop control mode of frequency inverter
ON Torque control mode
OFF Speed control mode
35: Minimum torque limiting set value selection
This function is applied to switch minimum torque limiting set value of frequency inverter (negative torque
limiting) between minimum torque limiting 1 and minimum torque limiting 2. See switching status as following
table:
Table 7-11 Minimum torque limiting selection contrast table of frequency inverter
Terminal status Minimum torque limiting set value of frequency inverter
ON Minimum torque limiting 2
OFF Minimum torque limiting 1
36: Maximum torque limiting set value selection
This function is applied to switch maximum torque limiting set value of frequency inverter between maximum
torque limiting 1 and maximum torque limiting 2. See switching status as following table:
Table 7-12 Maximum torque limiting selection contrast table of frequency inverter
Terminal status Maximum torque limiting set value of frequency inverter
ON Maximum torque limiting 2
OFF Maximum torque limiting 1
40: RS485 external/Standard operation panel switching
When two operation panels are inserted to frequency inverter at the same time, one is for master control
panel switching, and the other is only for monitoring, and the order cannot be inputted in.
Table 7-13 Control command channel switching and selecting table for frequency inverter
Terminal state Control command channel of frequency inverter
ON RS485 external panel
OFF Standard operation panel
42: Start permission
When parameter F0.4.37 is set as ###1or ###2, the function terminal is valid.
43: Running permission
When parameter F0.4.37 is set as #1## or #2##, the function terminal is valid.