165
SVAN 958A User Manual
Table B.1.38. Minimum results of 1/1 OCTAVE analysis in one channel
Word
number
Name / Value
Comment
0
0xnn2E
[2E, nn=block length]
1
LowestFreq
the lowest 1/1 OCTAVE frequency (*100 Hz)
2
Noct
number of 1/1 OCTAVE values
3
NoctTot
number of TOTAL values = 3
4 - length
block
MinOctave[i]
minimum result of the 1/1 octave analysis (*100 dB);
i = 1…NOct + NOctTot
Table B.1.39. Maximum results of 1/3 OCTAVE analysis in one channel
Word
number
Name / Value
Comment
0
0xnn2F
[2F, nn=block length]
1
LowestFreq
the lowest 1/3 OCTAVE frequency (*100 Hz)
2
Nter
number of 1/3 OCTAVE values
3
NterTot
number of TOTAL values = 3
4 - length
block
MaxTercje[I]
maximum result of the 1/3 octave analysis (*100 dB);
i = 1…NTer + NterTot
Table B.1.40. Minimum results of 1/3 OCTAVE analysis in one channel
Word
number
Name / Value
Comment
0
0xnn30
[30, nn=block length]
1
LowestFreq
the lowest 1/3 OCTAVE frequency (*100 Hz)
2
Nter
number of 1/3 OCTAVE values
3
NterTot
number of TOTAL values = 3
4 - length
block
MinTercje[I]
minimum result of the 1/3 octave analysis (*100 dB);
i = 1…NTer + NterTot
Note: The TOTAL values, calculated in the case of sound measurements, correspond
to the A, C and LIN filters respectively. The TOTAL values, calculated in the case of vibration
measurements, correspond to the HP, CH and CH filters respectively, where CH denotes the filter used in
the channel for Level Meter measurement.