CARE AND MAINTENANCE 7
MHL380 D 7.37
O = Inspection, maintenance
X = Replace
Operating
hours
Perform work with machine at operating temperature!
every 500
every 1000
at least once
a year
25
Tighten the fastening screws on the counterweight (1000 Nm).
O O
26
Check the bearing of the movable cab (h Chapter 7.7)
O O
27
Check that the door catch is in perfect working order and replace if necessary.
O
O
28
Check the bushings and pins of the loading equipment and adjust to "no play"
O
O
29
Check electrical indicating and warning elements, as well as the lighting system
O
O
30
Check the control elements for ease of operation and adjust if necessary.
O O
31
Check the function of the hydraulic axle lock and vent the oscillating axle cylin-
ders.
O
O
32
Check the function of the steering.
O
O
33 Check the condition and function of the outriggers.
O
O
34
Visual inspection of all steel parts and components for material cracks, defor-
mation, wear, external damage, completeness, etc.
O O
35
Check tightness of all pipes, hoses, control valves, hose-rupture safety valves,
hydraulic pumps, cylinders, etc.
h When tightening hose and line connections, the screw couplings must be
locked to prevent rotation.
O
O
36
Check function of brakes and brake disc play and vent brakes.
O
O
37 Check the pump drive.
O
O
38
Check that the slewing ring fastening screws are seated correctly.
O O
39
Secure fastening of slewing ring attachment, swing gear, swing gear motor
O
O
40
Lubricate the machine according to overview of lubricating points
h Chapter 7.7
41
Check function, condition and completeness of safety equipment.
O
O
42
Hydraulic function check with pressure function test
O
O
43
Replace the air filter insert for the supplementary heating
4)
O
X
44
Change the filter material for the air filter (hot water heating)
4)
O
X
45 Check V-belt tension, generator.
O
X
46
Check the condition, V-belt tension and filter for the air conditioning.
O O
47
Replace hydraulic oil tank ventilation filter.
X
X
48
Test run and test work
O
O
49
Initial inspection cards and return to TEREX | Fuchs.
O
4) The intervals should be shortened in dusty ambient conditions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Terex Fuchs MHL380 D and is the answer not in the manual?

Terex Fuchs MHL380 D Specifications

General IconGeneral
BrandTerex
ModelFuchs MHL380 D
CategoryConstruction Equipment
LanguageEnglish

Related product manuals