CARE AND MAINTENANCE 7
MHL380 D 7.37
O = Inspection, maintenance
X = Replace
Perform work with machine at operating temperature!
every 500
every 1000
a year
Tighten the fastening screws on the counterweight (1000 Nm).
O O
Check the bearing of the movable cab (h Chapter 7.7)
O O
Check that the door catch is in perfect working order and replace if necessary.
Check the bushings and pins of the loading equipment and adjust to "no play"
Check electrical indicating and warning elements, as well as the lighting system
Check the control elements for ease of operation and adjust if necessary.
O O
Check the function of the hydraulic axle lock and vent the oscillating axle cylin-
ders.
Check the function of the steering.
33 Check the condition and function of the outriggers.
Visual inspection of all steel parts and components for material cracks, defor-
mation, wear, external damage, completeness, etc.
O O
Check tightness of all pipes, hoses, control valves, hose-rupture safety valves,
hydraulic pumps, cylinders, etc.
h When tightening hose and line connections, the screw couplings must be
locked to prevent rotation.
Check function of brakes and brake disc play and vent brakes.
37 Check the pump drive.
Check that the slewing ring fastening screws are seated correctly.
O O
Secure fastening of slewing ring attachment, swing gear, swing gear motor
Lubricate the machine according to overview of lubricating points
h Chapter 7.7
Check function, condition and completeness of safety equipment.
Hydraulic function check with pressure function test
Replace the air filter insert for the supplementary heating
4)
Change the filter material for the air filter (hot water heating)
4)
45 Check V-belt tension, generator.
Check the condition, V-belt tension and filter for the air conditioning.
O O
Replace hydraulic oil tank ventilation filter.
Initial inspection cards and return to TEREX | Fuchs.