EasyManua.ls Logo

Topcon HiPer Plus - Page 146

Topcon HiPer Plus
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Topcon HiPer+ Operator’s Manual
5-6
The corresponding
receiver options may
be disabled or expired.
See “Checking an OAF” on
page 4-14 for details on how to
check current options.
Enable the corresponding receiver
options.
Contact your dealer to purchase
current receiver options.
There are not enough
common satellites. In
order to obtain a fixed
solution, the Base and
Rover should track at
least five common
satellites.
Ensure that both the Rover and Base
receivers use the same, and updated,
almanac. See “Collecting Almanacs”
on page 2-49.
Check the elevation masks of the
Rover and Base receivers; they
should be the same. See page 2-25
for information on setting the
elevation mask.
Poor satellite geometry
(PDOP/GDOP values
are too high).
Conduct your survey when PDOP
values are low.
The elevation mask is
above 15 degrees.
Lower the elevation mask.
See page 2-25 for information on
setting the elevation mask.
The receiver and the
antenna have a poor
connection.
Ensure the cable is undamaged.
Check the cable connector
attachment to the receiver. Remove
and reattach the cable connector to
ensure a secure connection.
The Base and Rover
modems are set to
different radio
channels.
Set the Base and Rover receivers to
the same radio channel.
See “Radio Configuration” on
page 2-30.

Table of Contents

Related product manuals