Troubleshooting
Topcon HiPer+ Operator’s Manual
5-10
The settings for Port B
may have been
changed.
The settings for Port B are: 115200
baud rate, 8 data bits, 1 stop bit, no
parity, and no handshaking.
Try enabling RTS/CTS handshaking
for Port B. Do not change other
settings.
The corresponding
receiver options may
be disabled or expired.
See “Checking an OAF” on
page 4-14 for details on how to
check current options.
Enable the corresponding receiver
options.
Contact your dealer to purchase
current receiver options.
Error Message
Can’t find Bluetooth.
Causes Solution
The receiver’s Slot 3 is
turned off.
1. Connect your receiver and a
computer using an RS232 cable
(see “Establishing an RS232 Cable
Connection” on page 2-7).
2. Click Configuration->Receiver
->General.
3. In the Turn on/off Slots area,
enable the Slot 3 (B) check box.
The Bluetooth module
is linked with another
device.
Close the connection with the device,
then connect to your receiver.