HiPer+ Specifications
1-866-4TOPCON www.topconpositioning.com
B-5
Input voltage 6 to 28 V DC (for work)
9 to 28 V DC (for charge battery)
Minimum Charge Current >=2 Amp
Consumption Typical: 2.5W
Maximum: 2.7W
On-board Backup battery for timekeeping and almanac data
storage
10 years minimum operation
Environment
Operating
temperature
-30 C° to + 60 C° with batteries
Storage temperature -40 C° to +75 C° with batteries
Physical
Enclosure Aluminum extrusion, rainproof
Color Topcon Yellow
Dimensions W:158.5 x H:113 x D:173 mm
Weight 1.72 kg
Antenna Internal
Battery Two internal
Controller External
Mounting 5/8-11
Seals Silicon (molding in Color)
Table B-1. HiPer+ Specifications