Specifications
Topcon HiPer+ Operator’s Manual
B-6
Keys Three keys:
Power – On/Off
Function (FN) – start/stop data logging; switch
information mode.
Reset – receiver hardware reset
LEDs Four LEDs:
STAT – satellite and receiver status
REC – record and data status
BATT – battery status
RX – modem status
NMEA
NMEA version Ver. 2.1, 2.2, 2.3, 3.0 output
Messages GGA, GLL, GNS, GRS, GSA, GST, GSV, HDT,
RMC, VTG, ZDA, ROT
Output interval 1Hz standard; 5, 10, 20Hz optional
DGPS
Correction format RTCM SC104 Ver 2.1, 2.2, and 2.3
RTCM message type 1, 3, 9, 31, 32, 34; user selectable
Process interval 1Hz standard; 5, 10, 20Hz optional
Output interval for
RTCM correction
data
1Hz standard; 5, 10, 20Hz optional
Elevation mask
0 to 90 deg (independent of data logging
)
Multi-base DGPS Differential correction select mode: Nearest, Mix,
Best (optional)
Table B-1. HiPer+ Specifications
Component Details