CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
B-EP Series
6-47
Ciiijjj: No. of cells (Omissible. If this parameter is omitted, it is automatically set.)
iii: No. of cells in the X direction 000 to 144
jjj: No. of cells in the Y direction 000 to 144
NOTE: Cell setting varies according to the ECC type.
ECC000 to ECC140 ECC200
No. of cells to be
designated
Odd numbers only Even numbers only
Min./Max. No. of cells 9 × 9 to 49 × 49 10 × 10 to 144 × 144
Rectangular code None 18 × 8
32 × 8
26 × 12
36 × 12
36 × 16
48 × 16
• When this parameter is omitted, the number of cells is automatically set.
Also, when data except for the above values is designated for Nos. of cells in
the X and Y directions, the number of cells is automatically set.
Jkkllmmmnnn: Connection setting
(Omissible: No connection if this parameter is omitted)
kk: Code number 01 to 16
ll: No. of divided codes 01 to 16
mmm: ID number 001 to 254
nnn: ID number 2 001 to 254
NOTE: It is effective only when ECC200 is selected.
ooo: Data length
000 to 100
NOTES: 1. A two-digit value (00 to 99) is also available.
2. When “00” is designated, the length is equivalent to the data
sent by the Data Print Command (data which is delimited by
[LF].)
3. When “00” is designated, the length is equivalent to the data
sent by the Data Print Command. It corresponds for up to
2000 digits.
p: Data code
1 (Fixed value): JIS8 code
q: Reserved area
0: Fixed value