EasyManua.ls Logo

WinGD X62DF - Page 806

Default Icon
897 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: You must first start the engine control system before you start the
spare LDU-20 in the ECR. The spare LDU-20 in the ECR will be
synchronized with the master LDU-20 in the local control panel through
the Ethernet cable.
1.14 Set to ON the LDU-20.
1.15 Do a check to make sure that the LDU-20 operates correctly. If you get an error
message, speak to or send a message to WinGD.
1.16 If applicable, start the engine at the remote control system (RCS), refer to the
Operation Manual.
NOTE: The engine will do a standard start.
2 To install an LDU-20 in the engine control room do the steps that follow:
NOTE: To replace a defective LDU-20 in the ECR, you must use only the spare item.
Do not use the LDU-20 from the local control panel.
2.1 Get access to the rear of the LDU-20. Refer to the documentation of the control
panel manufacturer.
2.2 Do Step 1.12 to Step 1.16.
CLOSE UP
None
X62DF
AA00-9606-00AAA-720A-A
Maintenance Manual LDU-20 - install
Winterthur Gas & Diesel Ltd.
- 806 - Issue 002 2020-10

Table of Contents

Related product manuals