1128600 SmartPAC 2 with WPC 2000 Integration User Manual
1-8 Introduction
WPC 2000 Operator Station
Figure 1-2 identifies the switches and indicator lamps on a Wintriss Operator Station. (The
configuration with side-mounted Run/Inch palm switches is shown.) Functions of Operator
Station components are provided following the figure.
Run/Inch Palm Switches (2)–Initiate press action when both switches are pressed at the
same time (Two-hand mode) or when only the left switch is pressed (One-hand mode).
Prior Act Lamp and Switch–An arming device that must be pressed in Continuous Two-
hand and Continuous Foot operating modes before a stroke can be initiated. When the switch
is pressed, the lamp illuminates for 8 seconds, indicating the interval within which the
operator must press the Run/Inch buttons or Foot Switch in order to stroke the press. Also
used in Automatic Single-stroke operation (see page 6-49).
Emergency Stop Switch–Stops the press immediately when you push it. The switch is not
spring-loaded, so you must pull it back to its original position to clear the emergency stop
(F13) fault (see page 7-8).
Top Stop Switch–Stops the press at the top of its stroke when pressed during Continuous
operation.
Palm Time Lamp–Illuminates when one Run/Inch palm button is depressed, turning off after
the 1/2-second palm time (“synchronous” time in ANSI terminology) on a standalone
Operator Station or the 5-second concurrent time on multiple Operator Stations. The other
palm button on a standalone Op. Station or all pairs of buttons on multiple Operator Stations
must be pressed before the lamp turns off in order to initiate a stroke.
Mute Lamp–Illuminates during muting of the light curtain on the upstroke. Requires
installation of a Shadow light curtain and optional light curtain muting firmware.
Figure 1-2. Operator Station Components (Side-mounted Run/Inch Palm Buttons)
PRIOR ACT
switch
PALM TIME
lamp
MUTE
lamp
TOP STOP
switch
EMERGENCY STOP
switch
RUN / INCH
palm switches
RUN/
INCH
RUN/
INCH
PALM
TIME
PRIOR
ACT
MUTE
TOP
STOP
WINTRISS
E
M
E
R
G
E
N
C
Y
S
T
O
P

Table of Contents

Other manuals for Wintriss SmartPAC 2