1128600 SmartPAC 2 with WPC 2000 Integration User Manual
7-16 Fault Messages
Light Curtain Faults
-and-
Problem: Light curtain A (fault #60) or light curtain B (fault #61) failed the WPC 2000
internal test.
Remedy: Check to make sure that the light curtain is wired correctly, referring to figures 4,
14, 15, 20, 21, 23, and 24 at the back of the manual if you have Shadow light
curtains, referring to the appropriate user manual if you have another product. If
you need additional assistance, contact Wintriss Tech. Support.
Problem: Two pairs of light curtains are wired to WPC 2000, but only one pair has been
enabled on option switch 6 on the Press Control Option Switch Menu.
Remedy: Set option switch 6 for dual light curtains (see page 4-38).
Problem: Light curtain A is obstructed during the stroke.
Remedy: Remove the obstruction.
Problem: Light curtain B is obstructed during the stroke.
Remedy: Remove the obstruction.
F60 or H60
F61 or H61
F62
F63
F64

Table of Contents