9.4 Monitoring Product Life
9.4.3 Preventative Maintenance
9-16
9.4.3
Preventative Maintenance
You can use preventative maintenance warnings for preventative maintenance. The SERVO-
PACK can notify the host controller when it is time to replace any of the main parts.
Preventative Maintenance Warning
An A.9b0 warning (Preventative Maintenance Warning) is detected when any of the following
service life prediction values drops to 10% or less: SERVOPACK built-in fan life, capacitor life,
inrush current limiting circuit life, and dynamic brake circuit life. You can change the setting of
Pn00F = n.X to enable or disable these warnings.
Parameter Description
When
Enabled
Classifi-
cation
Pn00F
n.
0
(default setting)
Do not detect preventative maintenance warnings.
After
restart
Setup
n.
1 Detect preventative maintenance warnings.