EasyManua.ls Logo

YASKAWA E-7S SERVOPACK SGD7S - Page 381

YASKAWA E-7S SERVOPACK SGD7S
671 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.2 SERVOPACK Commissioning Procedure
10-4
4
Perform a program jog
operation.
Items to Check
Does the fully-closed
system operate correctly
for the SERVOPACK
without a load?
Perform a program jog operation
and confirm that the travel dis-
tance is the same as the reference
value in Pn531.
When you perform program jog
operation, start from a low speed
and gradually increase the speed.
Pn530 to Pn536 (program
jog operation-related
parameters)
SERVO-
PACK
5
Operate the SERVO-
PACK.
Items to Check
Does the fully-closed
system operate correctly,
including the host con-
troller?
Input a position reference and con-
firm that the SERVOPACK oper-
ates correctly.
Start from a low speed and gradu-
ally increase the speed.
Host con-
troller
Continued from previous page.
Step Description Operation
Required Parameter
Settings
Con-
trolling
Device

Table of Contents

Related product manuals