EasyManua.ls Logo

YASKAWA E-7S SERVOPACK SGD7S

YASKAWA E-7S SERVOPACK SGD7S
671 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15.2 Alarm Displays
15.2.2 Troubleshooting Alarms
15-14
A.042:
Parameter Com-
bination Error
The speed of program
jog operation went
below the setting
range when the elec-
tronic gear ratio
(Pn20E/Pn210) or the
Servomotor was
changed.
Check to see if the
detection conditions
*1
are satisfied.
Decrease the setting of
the electronic gear ratio
(Pn20E/Pn210).
page 5-42
The speed of program
jog operation went
below the setting
range when Pn533 or
Pn585 (Program Jog
Operation Speed) was
changed.
Check to see if the
detection conditions
*1
are satisfied.
Increase the setting of
Pn533 or Pn585.
page 7-14
The movement speed
of advanced autotun-
ing went below the
setting range when
the electronic gear
ratio (Pn20E/ Pn210)
or the Servomotor
was changed.
Check to see if the
detection conditions
*2
are satisfied.
Decrease the setting of
the electronic gear ratio
(Pn20E/Pn210).
page 5-42
A.044:
Semi-Closed/
Fully-Closed
Loop Control
Parameter
Setting Error
The setting of the
Fully-Closed Module
does not match the
setting of Pn002 =
n.X (External
Encoder Usage).
Check the setting of
Pn002 = n.X.
Make sure that the setting
of the Fully-closed Mod-
ule agrees with the setting
of Pn002 = n.X.
page 10-5
A.04A:
Parameter Set-
ting Error 2
A parameter reserved
by the system was
changed.
Set the following reserved
parameters to the default
settings.
Pn200.2
Pn207.1
Pn50A.0
Pn50A.1
Pn50A.2
Pn50C
Pn50D
A.050:
Combination
Error
(The capacities of
the SERVOPACK
and Servomotor
do not match.)
The SERVOPACK and
Servomotor capaci-
ties do not match
each other.
Confirm that the follow-
ing condition is met:
1/4
(Servomotor
capacity/SERVOPACK
capacity)
4
Select a proper combina-
tion of the SERVOPACK
and Servomotor capaci-
ties.
page 1-15
A failure occurred in
the encoder.
Replace the encoder
and check to see if the
alarm still occurs.
Replace the Servomotor
or encoder.
A failure occurred in
the SERVOPACK.
The SERVOPACK may be
faulty. Replace the SER-
VOPACK.
A.051:
Unsupported
Device Alarm
The motor parameter
file was not written to
the linear encoder.
(This applies only
when not using a
Serial Converter Unit.)
Check to see if the
motor parameter file
was written to the lin-
ear encoder.
Write the motor parame-
ter file to the linear
encoder.
page 5-17
An unsupported Serial
Converter Unit or
encoder (e.g., an
external encoder) is
connected to the
SERVOPACK.
Check the product
combination specifica-
tions.
Change to a correct com-
bination of models.
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents

Related product manuals