EasyManua.ls Logo

YASKAWA E-7S SERVOPACK SGD7S

YASKAWA E-7S SERVOPACK SGD7S
671 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15.2 Alarm Displays
15.2.2 Troubleshooting Alarms
15-34
A.C92:
Encoder Commu-
nications Timer
Error
Noise entered on the
signal line from the
encoder.
Implement countermea-
sures against noise for the
encoder wiring.
page 4-6
Excessive vibration or
shock was applied to
the encoder.
Check the operating
conditions.
Reduce machine vibra-
tion.
Correctly install the Ser-
vomotor or linear encoder.
A failure occurred in
the encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
A.CA0:
Encoder Parame-
ter Error
A failure occurred in
the encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
A failure occurred in
the SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents

Related product manuals