6.2 Communication with Other MP Series
6.2.4 When the MP2300S Acts as Master (ladder program which uses a MSG-SND function)
6-64
Parameter list setting example for message receive function
A parameter list setting example is as follows when receiving messages from a transmit source using the connec-
tion with a connection number = 3:
Note: IN: Input, OUT: Output, SYS: For system use
Example of Using the Message Receive Function in a Ladder Program
A ladder program for receiving messages in the remote equipment (MP2300) side is similar to that in ( 2 ) How to
Set up the Remote Device (MP2300) to Be Connected of 6.2.3 When the MP2300S Acts as Master (I/O message
communication function is used).
However, change Communication buffer channel number and Connection number respectively based on the I/O
definition and parameter list settings.
( 3 ) How to Start Communication
1. MP2300 side starts to receive the messages.
As the sample ladder program starts the message receive operation just after the system startup, you don
t need to
operate it particularly. Normally, accept the default.
2. Turn Execute ON for the message transmit function in the MP2300S side to transmit messages.
The sample ladder program is created to transmit a message every one second when five seconds elapsed after
the low-speed scan (or high-speed scan) startup.
The way to change the message transmission interval is similar to that in ( 3 ) How to Start Communications of
6.2.1 When the MP2300S Acts as Slave (automatic receive function is used).
Table 6.15 Parameter List Setting Example1 (parameter list start address Param = DA00000)
Register
Number
Setting
Value
Parameter
Number
IN/OUT Remarks
DW00000
PARAM00 OUT
Process result
DW00001
PARAM01 OUT
Status
DW00002
00003 PARAM02 IN
Connection number = 3 (For receiving read operation)
DW00003
PARAM03 OUT
Option
DW00004
PARAM04 OUT
Function code
DW00005
PARAM05 OUT
Data address
DW00006
PARAM06 OUT
Data size
DW00007
PARAM07 OUT
Remote CPU number
DW00008
00000 PARAM08 IN
Coil offset = 0 word
DW00009
00000 PARAM09 IN
Input relay offset = 0 word
DW00010
00000 PARAM10 IN
Input register offset = 0 word
DW00011
00000 PARAM11 IN
Holding register offset = 0 word
DW00012
00000 PARAM12 IN
Writable address lower limit = MW00000
DW00013
65534 PARAM13 IN
Writable address upper limit = MW65534
DW00014
PARAM14 SYS
Reserved by the system. (Zero clear at startup)
DW00015
PARAM15 SYS
Reserved by the system.
DW00016
PARAM16 SYS
Reserved by the system.