Appendix F Simple Connection Function of the Engineering Tool
F.1 Preparation
A-47
Appendices
Appendix F Simple Connection Function of the Engineering Tool
This section explains how to set up a communication process connecting the MPE720 and MP2300S.
In MPE720 Ver.6, set the communication process on the MPE720 screen.
Prepare the following equipment to carry out this procedure:
F.1 Preparation
( 1 ) Controller
( 2 ) Personal Computer
( 3 ) Necessary Others
F.2 Procedure
1. Turn OFF the MP2300S 24-VDC power supply.
2. Wire MPE720 and MP2300S.
Product Name Model Q'ty
MP2300S
JEPMC-MP2300S-E
1
Product Name Model Q'ty
MPE720
CPMC-MPE770 (Ver.6.04 or later)
1
Ethernet Communication
Cable
Any Commercial product
Ethernet cross cable (category 5 or more)
1
Personal Computer Main Unit
Any Commercial product
1
Name Specification Q'ty
24-VDC Power Supply
Current capacity 2 A or more
1
Personal computer
with MPE720
24-VDC
Power supply
Machine controller
Ethernet communication cable
&%
4.;
176
'VJGTPGV
&%
8
.+0-
/
0V
MP2300S
Optional module
;#5-#9#
6'56
4&;
#./
/6:
64:
470
'44
$#6
+2
59
59
/10
%0()
+06
572
5612
$#66'4;
㪧㪦㪮㪜㪩
'
M-I/II
+0+6
01
01
'
6'56