Appendix B  SERVOPACK Parameter Data Flow
B.1  Operations and Parameter Data Flow
A-22
2. The following figure shows an example of the SERVOPACK Tab in the SVB Definition Window.  The 
values in Current Value are different from the values in Input Data. 
( 4 ) SERVOPACK Parameters Saved in the MPE720 
The data flow for SERVOPACK parameters is as follows when File - Save is selected from the SERVOPACK Tab 
Page: 
1. The MPE720 writes all the parameters in Input Data currently displayed on SERVOPACK Tab Page of 
the relevant axis to the followings. 
• HDD (hard disk) of the personal computer
• SDRAM of MP2300S
• RAM and EEPROM of the SERVOPACK
2. After having completed writing the parameters, the MPE720 updates the values in Current Value on 
the SERVOPACK Tab Page with the SERVOPACK parameter values stored in the RAM. 
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Input
Data
MPE720  㧔online㧕
HDD in personal computer
Display
Current
Value
Input
Data
Flash 
Memory
SERVOPACK 
Parameters 
(All Axes) 
Parameters 
System 
Software
Control 
Software
SERVOPACK SERVOPACK
Send Send 
MP2300S