2.2  Basic Module
2.2.7  M-EXECUTOR Module (Motion Program Executor)
2-55
Specifications and Functions
( 4 ) Detailed Screen
This section describes the M-EXECUTOR detail screen.
 Program Definition Screen (M-EXECUTOR (list display) screen)
The program definition screen allows you to register a motion or sequence program to run. 
Programs are executed according to the scan, in ascending numeric order.
A white cell can be set by the user, and a grey cell cannot be set by the user.
c Individual display
Shows M-EXECUTOR (individual display) screen.
d Program definition number
Sets the number of program definitions registered in the M-EXECUTOR Module.
The valid range is 0-16 (8 by default).
e No.
Shows the program execution order. Processed according to the scan in ascending numeric order.
f D
Enables/disables the definition. Uncheck to enable the definition.