Appendix F Simple Connection Function of the Engineering Tool
F.2 Procedure
A-48
3. Turn ON E-INIT of DIP switch (SW2) in the MP2300S main unit.
4. Turn ON the 24-VDC power supply of the MP2300S, and confirm that the RDY, RUN, and IP LEDs are
lit on the MP2300S main unit.
When the IP LED is lit, you can confirm that the MP2300S side has successfully retrieved an IP
address.
5. Double-click the icon on the personal computer desktop to start up MPE720 Ver6.
6. Create a new PLC folder.
7. Click Communications Setting.
4
3
E-INIT 2
E-TEST1
OFF ON
RDY
A
LM
MTX BAT
RUN
ERR
RDY
ALM
MTX BAT
RUN
ERR
TRX IP
TRX IP
:Lit
:Unlit