Removing the axis-2 mechanical stop
NoteAction
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
xx1500000488
Remove the mechanical stop by removing
the two screws and washers.
2
Refitting the mechanical stop
Use these procedures to refit the mechanical stop.
Refitting the axis-2 mechanical stop
NoteAction
Mechanical stop for axis 2: 3HAC047602-
001
Refit the mechanical stop with the screws
and washers.
1
Screws: 3HAB3409-241 (2 pcs).
Tightening torque: 0.4 Nm.
xx1500000488