Electrical
Troubleshooting Guide
IRB6400 M94A
Page 11 - 17
Inputs & Outputs
11.3.2 Relay Unit (Conn. option 37X)
Digital Inputs Technical Data:
- Optically isolated
- Rated voltage supply:
24 VDC (19 - 35 VDC)
- Logical voltage levels:
“1” 15 - 35 VDC
“0” 0 - 5 VDC
- Input current at rated input voltage:
5.5 mA
- Maximum potential difference:
500V
- Time intervals:
< or = 8ms (hardware)
plus 1-11ms(software)
- System board time intervals:
< or = 1.5 ms (hardware)
plus <2ms (software)
Digital Outputs Technical Data:
- Optically isolated and short circuit protected
- Voltage supply:
24 VDC (19 - 35 VDC)
- Minimum voltage drop on output:
2 V
- Load per output:
200 mA
- Load per group of 8 outputs:
1 A
- Maximum potential difference:
500 V
- Time intervals:
<150 ms (hardware)
plus <2 ms (software)
Digital Outputs Technical Data:
Load per output:
4 A
Load per group of 8 outputs:
6.3 A
Voltage range (source):
250 VAC
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com