Agilent N5181A/82A MXG Signal Generators SCPI Command Reference 89
System Commands
Output Subsystem (:OUTPut)
Output Subsystem (:OUTPut)
:BLANking:AUTO
Supported All
:OUTPut:BLANking:AUTO ON|OFF|1|0
:OUTPut:BLANKing:AUTO?
This command turns the RF output on or off during frequency band changes. Frequency band
changes can cause the signal generator’s RF output to fluctuate. The output blanking function, when
active, turns off the RF output until the frequency and power settles.
ON(1) The RF output turns off when crossing a frequency band.
OFF(0) The RF output stays on, if possible, when crossing a frequency band. Refer to the
Data sheet.
*RST 1
Key Entry Output Blanking Off On Auto
Remarks Refer to the signal generator’s data sheet for information on frequency switching
speeds, settling times, and frequency band information.
:BLANking:STATe
Supported All
:OUTPut:BLANking:STATe ON|OFF|1|0
:OUTPut:BLANKing:STATe?
This command enables or disables the RF output blanking state.
ON(1) The RF output turns off during frequency changes.
OFF(0) The RF output stays on, if possible, during frequency changes. Refer to the Data
sheet.
*RST 0
Remarks Refer to the signal generator’s data sheet for information on frequency switching
speeds, settling times, and frequency band information.
:MODulation[:STATe]
Supported All
:OUTPut:MODulation[:STATe] ON|OFF|1|0
:OUTPut:MODulation[:STATe]?
This command enables or disables the modulation of the RF output with the currently active
modulation type(s).
*RST 1
Key Entry Mod On/Off