160 Agilent N5181A/82A MXG Signal Generators SCPI Command Reference
Component Test Digital Commands
Dual ARB Subsystem–Option 651/652/654 ([:SOURce]:RADio[1]:ARB)
:TRIGger[:SOURce]
Supported N5182A with Option 651/652/654
[:SOURce]:RADio:ARB:TRIGger[:SOURce] KEY|EXT|BUS
[:SOURce]:RADio:ARB:TRIGger[:SOURce]?
This command sets the trigger source.
For more information on triggering, see “:TRIGger:TYPE” on page 156. The following list describes the
command choices:
KEY This choice enables manual triggering by pressing the front-panel Trigger hardkey.
EXT An externally applied signal triggers the waveform. This is the only choice that
works with gating. The following conditions affect an external trigger:
The input connector selected for the trigger signal. You have a choice between
the rear- panel PATTERN TRIG IN connector or the PATT TRIG IN 2 pin on the
rear- panel AUXILIARY I/O connector. To make the connector selection, see
“:TRIGger[:SOURce]:EXTernal[:SOURce]” on page 162.
For more information on the connectors and on connecting the cables, see the
User’s Guide.
The trigger signal polarity:
gating mode, see “:TRIGger:TYPE:GATE:ACTive on page 158
continuous and single modes, see “:TRIGger[:SOURce]:EXTernal:SLOPe” on
page 161
The time delay between when the Agilent MXG receives a trigger and when the
waveform responds to the trigger. There are two parts to setting the delay:
setting the amount of delay, see “:TRIGger[SOURce]:EXTernal:DELay” on
page 160
turning the delay on, see “:TRIGger[:SOURce]:EXTernal:DELay:STATe” on
page 161
BUS This choice enables triggering over the GPIB or LAN using the *TRG or GET
commands or the AUXILIARY INTERFACE (USB) using the *TRG command.
*RST EXT
:TRIGger[SOURce]:EXTernal:DELay
Supported N5182A with Option 651/652/654
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay <value>
[:SOURce]:RADio:ARB:TRIGger[:SOURce]:EXTernal:DELay?
This command sets the amount of time to delay the Agilent MXGs response to an external trigger.
The delay is a path (time) delay between when the Agilent MXG receives the trigger and when it
responds to the trigger. For example, configuring a trigger delay of two seconds, causes the Agilent
MXG to wait two seconds after receipt of the trigger before the Agilent MXG plays the waveform.
Key Entry Trigger Key Ext Bus

Table of Contents