Agilent N5181A/82A MXG Signal Generators SCPI Command Reference 35
Basic Function Commands
Frequency Subsystem ([:SOURce])
Key Entry Channel Number
:FREQuency:CHANnels[:STATe]
Supported All Models
[:SOURce]:FREQuency:CHANnels[:STATe] ON|OFF|1|0
[:SOURce]:FREQuency:CHANnels[:STATe]?
This command enables or disables the frequency channel and band selection. The signal generator
frequency will be set to the channel frequency when the state is on. To set frequency channel bands
refer to “:FREQuency:CHANnels:BAND” on page 32.
Example
:FREQ:CHAN ON
The preceding example turns on the frequency channel.
*RST 0
Key Entry Freq Channels Off On
:FREQuency:FIXed
Supported All Models
[:SOURce]:FREQuency:FIXed <value><unit>
[:SOURce]:FREQuency:FIXed?
This command sets the signal generator output frequency.
Remarks A frequency change may affect the current output power. Refer to
“[:LEVel][:IMMediate][:AMPLitude]” on page 57 for the correct specified frequency
and amplitude settings. To set the frequency mode refer to “:FREQuency:MODE”
on page 36. Option 501 is specific to the N5181A.
PHS Standard: 1–255
DECT Standard: 0–9
*RST Option 501:+1.0000000000000E+09
Option 503: +3.0000000000000E+09
Option 506: +6.0000000000000E+09
Range Option 501: 100kHz–1GHz
Option 503: 100kHz–3GHz
Option 506: 100kHz–6GHz