72 Agilent N5181A/82A MXG Signal Generators SCPI Command Reference
System Commands
Display Subsystem (:DISPlay)
Remarks The setting enabled by this command is not affected by signal generator power- on,
preset, or *RST.
:CAPTure
Supported All Models
:DISPlay:CAPTure
This event command enables the user to capture the current display and store it in the signal
generator’s memory.
Remarks The display capture is stored as DISPLAY.BMP in the Binary file system. This file
is overwritten with each subsequent display capture. The file can be down- loaded
in the following manner:
1. Log on to the signal generator using ftp.
2. Change (cd) to the BIN directory.
3. Retrieve the file by using the get command or by using the :MEM:DATA query
on page 81.
:CMAP:DEFaults
Supported All Models
:DISPlay:CMAP:DEFault [<palette:{BRIGht}|DARK|MONOchrome>]
This command selects the color palette for the instrument display.
Remarks The setting enabled by this command is not affected by signal generator power- on,
preset, or *RST.
:CONTrast
Supported All Models
:DISPlay:CONTrast <value>
:DISPlay:CONTrast?
This command sets the contrast of the LCD display. The contrast can be set to the maximum level
(1), minimum level (0), or in between by using fractional numeric values (0.001–0.999).
Range 0–1
Key Entry Display contrast hardkeys are located below the display.
Remarks The setting enabled by this command is not affected by signal generator power- on,
preset, or *RST.
Key Entry Bright Color Dark Color Monochrome