EasyManua.ls Logo

Agilent Technologies n5181a - Retrigger; Rscaling

Agilent Technologies n5181a
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Agilent N5181A/82A MXG Signal Generators SCPI Command Reference 153
Component Test Digital Commands
Dual ARB Subsystem–Option 651/652/654 ([:SOURce]:RADio[1]:ARB)
Key Entry Real-time Noise Off On
:RETRigger
Supported N5182A with Option 651/652/654
[:SOURce]:RADio[1]:ARB:RETRigger ON|OFF|1|0|IMMediate
[:SOURce]:RADio[1]:ARB:RETRigger?
This command enables or disables the ARB retriggering mode; the retrigger mode controls how the
retriggering function performs while a waveform is playing.
ON (1) This choice (Buffered Trigger) specifies that if a trigger occurs while a waveform
is playing, the waveform will retrigger at the end of the current waveform
sequence and play once more.
OFF (0) This choice (No Retrigger) specifies that if a trigger occurs while a waveform is
playing, the trigger will be ignored.
IMMediate This choice (Restart on Trigger) specifies that if a trigger occurs while a waveform
is playing, the waveform will reset and replay from the start immediately upon
receiving a trigger.
*RST ON
Remarks This command applies to the single trigger type only.
:RSCaling
Supported N5182A with Option 651/652/654
[:SOURce]:RADio[1]:ARB:RSCaling <value>
[:SOURce]:RADio[1]:ARB:RSCaling?
This command adjusts the scaling value in percent that is applied to a waveform while it is playing.
The variable <value> is expressed as a percentage. Runtime scaling does not alter the waveform data
file. For more information about runtime scaling, refer to the User’s Guide.
Example
:RAD:ARB:RSC 50
The preceding example applies a 50% scaling factor to the selected waveform.
*RST +7.00000000E+001
Range 1–100
Key Entry Waveform Runtime Scaling
Remarks Runtime scaling does not alter the waveform data file.
Key Entry No Retrigger Buffered Trigger Restart on Trigger

Table of Contents

Other manuals for Agilent Technologies n5181a

Related product manuals