Agilent N5181A/82A MXG Signal Generators SCPI Command Reference 91
System Commands
Route Subsystem (:ROUTe)
Route Subsystem (:ROUTe)
[:CONNector]:SOUT
Supported N5181A/82A
:ROUTe[:CONNectors]:SOUT SWEep|SETTled|PVIDeo
:ROUTe:CONNectors:SOUT?
This command selects a signal to be routed to the rear panel Sweep Out connector.
SWEep This choice routes the sweep out signal to the Sweep Out connector.
SETTled This choice routes the source settled signal to the Sweep Out connector.
PVIDeo This choice routes the pulse video signal to the Sweep Out connector.
*RST SWE
Key Entry Route Sweep Out
[:CONNector]:TOUT
Supported N5181A/82A
:ROUTe[:CONNectors]:TOUT SWEep|SETTled|PVIDeo|PSYNc
:ROUTe[:CONNectors]:TOUT?
This command selects a signal to be routed to the rear panel Trig Out connector.
SWEep This choice routes the sweep trigger out signal to the Trig Out connector.
SETTled This choice routes the source settled signal to the Trig Out connector.
PVIDeo This choice routes the pulse video signal to the Trig Out connector.
PSYNc This choice routes the pulse sync signal to the Trig Out connector.
*RST SWE
Key Entry Route Trig Out