Loading...
MULTI-REFLEXES 4099 HUB TERMINALS
Ed. 042/2 Réf. 3EH 21000 BSAA
The following terminals can be connected to option 4099:
- Alcatel Reflexes 2G sets with or without add-on modules (a maximum of 3 modules per option
4099).
- Alcatel Reflexes 3G sets with or without add-on modules or the 4091 CTI option (the 2 sub-groups
are mutually exclusive).
- a 4088 adapter with a V24 4083 ASM board.
The following terminals cannot be connected to option 4099:
- DECT 4070 IO/EO base stations
- Alcatel Reflexes 2G sets with options 4084 IS/ISW or 4085 AB and
- Alcatel Reflexes 3G sets with options 4093 ASY-CTI, 4094 ISW, 4094 ISW-CTI or 4095 AP.
Maximum distances from system to set
- 0.4-mm cable: 325 m
- 0.5-mm cable: 500 m
- 0.6-mm cable: 730 m

Table of Contents