EasyManuals Logo

Alcatel OmniPCX Office Technical Documentation

Alcatel OmniPCX Office
964 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #114 background imageLoading...
Page #114 background image
MULTI-REFLEXES 4099 HUB TERMINALS
Ed. 042/2 Réf. 3EH 21000 BSAA
The following terminals can be connected to option 4099:
- Alcatel Reflexes 2G sets with or without add-on modules (a maximum of 3 modules per option
4099).
- Alcatel Reflexes 3G sets with or without add-on modules or the 4091 CTI option (the 2 sub-groups
are mutually exclusive).
- a 4088 adapter with a V24 4083 ASM board.
The following terminals cannot be connected to option 4099:
- DECT 4070 IO/EO base stations
- Alcatel Reflexes 2G sets with options 4084 IS/ISW or 4085 AB and
- Alcatel Reflexes 3G sets with options 4093 ASY-CTI, 4094 ISW, 4094 ISW-CTI or 4095 AP.
Maximum distances from system to set
- 0.4-mm cable: 325 m
- 0.5-mm cable: 500 m
- 0.6-mm cable: 730 m

Table of Contents

Other manuals for Alcatel OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel OmniPCX Office and is the answer not in the manual?

Alcatel OmniPCX Office Specifications

General IconGeneral
VoIP SupportYes
SIP SupportYes
ISDN SupportYes
Analog SupportYes
Integrated Voice MailYes
Auto AttendantYes
ConferencingYes
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Network Interfaces10/100 Mbps Ethernet
Humidity10% to 90% non-condensing