3
CONFIGURING THE SYSTEMCALL SERVER : MOBILITY
Ed. 04 1/4Réf. 3EH 21000 BSAA
File
CONFIGURING THE SYSTEM
Configuring the system's DECT mobile functionality consists in programming the ARI number and the
GAP authentication code (if necessary). Both of these parameters must be completed before registering
a set on the system.
Before starting the DECT configuration, the numbering plan must be defined and the hardware con-
figuration (installing interface boards, recognizing sets, etc) completed.
ARI NUMBER
The ARI (Access Right Identifier) number identifies the system uniquely to mobiles. It contains 11 octal
digits (base 8). This number, assigned to an ETSI base by the installer, must be entered on installing
the system.
It is structured as follows:
- the ARC (Access Right Code) specifies the usage environment (private, public, etc); in the case of
Alcatel OmniPCX Office, a type-B ARI is allocated by the DECT protocol (ARC = 1, non modifiable)
- the EIC (Equipment Installer Code) is the number assigned by ETSI to each maker or distributor
offering DECT systems
- the FPN/S (Fixed Part Number/Subnumber) is a number entered by the installer: each system ins-
talled by the same installer must have a different number.
- To enter the system ARI number with PM5 (Expert View):
- To enter the system ARI number with MMC Station:
Important : The ARI number must be modified by the installer (in accordance with the above rules)
Select: System Miscellaneous-> DECT ARI/GAP Authentication-> enter the ARI number (the sys-
tem deduces the EIC, FPN and FPS fields automatically).
Select DECT -> ARI -> enter the ARI number and validate by clicking OK
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 1 1 0
ARC
EIC
0 0 0
1 1 1
1
FPN
FPS
ARI
100004
3
6074