EasyManuals Logo

Alcatel OmniPCX Office Technical Documentation

Alcatel OmniPCX Office
964 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #543 background imageLoading...
Page #543 background image
File
3
EXAMPLES USING ARSCALL SERVER : PRIVATE NETWORKS
Ed. 04 9/16Réf. 3EH 21000 BSAA
Remarks:
- the 2 lines of the private numbering plans of and make it possible to display the internal
number on the QSIG link.
NETWORK FORCING (forced dialing)
Purpose:
To force dialing on the QSIG link, then on the ATL and then on the public T0 accesses when a user
dials the public number 00147858835-39.
Settings:
Add the following elements to the PABX settings :
- Main numbering plan
-ARS table
Call description:
- (6): a user of dials 00147858835-39; 0 is interpreted by the main numbering plan as a public
ARS call with absorption of the 1st 0 and sends the number to the ARS table.
-(7): 0147858835-39 is recognized in the ARS table; it is replaced by 835-39 and sent on trunk
group list 1 (QSIG then ATL). If all of these trunk groups are busy, the system returns to consult the
ARS table and 0147858835-39 is sent on trunk group list 2 (public T0 access - the same goes for
overflow).
- (8): if the user dials a number other than 0147858835-39, the system sends this number to the
ARS table; the call is routed on the public T0 accesses.
Start End Base Function NMT Private
0 0 ARS Main trunk group Absorb No (6)
Network Prefix Ranges Substitute TrGp list Called/HH User com.
Public 01478588 35-39 8
01478588
1
2
Heterogen.
Heterogen.
(7)
Public Empty Empty Empty 2 Heterogen. (8)
A B
B
B
B

Table of Contents

Other manuals for Alcatel OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel OmniPCX Office and is the answer not in the manual?

Alcatel OmniPCX Office Specifications

General IconGeneral
VoIP SupportYes
SIP SupportYes
ISDN SupportYes
Analog SupportYes
Integrated Voice MailYes
Auto AttendantYes
ConferencingYes
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Network Interfaces10/100 Mbps Ethernet
Humidity10% to 90% non-condensing