CONFIGURATION OF STATIONSMMC STATION
Ed. 04 3/18Réf. 3EH 21000 BSAA
Press .
Enter the directory number of the station concerned.
STATUS OF THE STATION - OUTINS
Before allocating a terminal profile or carrying out a remote customization of a station, this station
must be switched off by pressing . After allocation, the station can be switched on again.
The station can be:
- In Service
-Logical OOS
- Physical OOS/Logical OOS: station not operational
- Physical OOS/Logical IS: station not regarded by the system (not declared or disconnected) and
switched off by the installer
Choosing + validation switches the station ON (IN SERVICE). Choosing + validation swit-
ches the station OFF (OUT OF SERVICE).
Nota : The Administrator session only allows the status of the station to be read.
TYPE OF STATION USED - TERMNL
Press .
The station directory number, type and software version are displayed.
SUBSCRIBER PROFILE - SUBPRO
Feature rights profile - FEATUR
Press followed by .
Choose the feature rights to be allocated to the station.
FEATURE RIGHTS VERY LOW LOW (de-
fault)
MIDDLE HIGH
Authorized camp-on YES YES YES
Protection against camp-on -- -- -- --
Authorized intrusion -- -- YES YES
Protection against intrusion (station busy) and
protection against intercom (station free)
-- -- YES YES
Protection against camp-on tone -- -- -- YES
Conference -- YES YES YES