EasyManua.ls Logo

Alcatel OmniPCX Office - Page 921

Alcatel OmniPCX Office
964 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
File
5
SYSTEM MESSAGESMAINTENANCE
Ed. 04 3/24Réf. 3EH 21000 BSAA
34 SOFTWARE KEY CHANGE CPU
board
(80)
INFO 0 = type of key (0= main key; 1
= CTI key)
INFO 1 = type of event
- 01: system booted with a key
which doesn’t correspond to the
system: the services are open for a
reduced period
- 02: system booted with a valid key
- 03: system booted with a key pro-
blem: the services are closed
- 12: valid key entered
- 13: the key present does not cor-
respond to the system: end of re-
duced period -> services closed
- 21: the key entered does not cor-
respond to the system -> services
open for a reduced period
- 32: the services are closed, valid
key entered -> services open
50 ISDN ACCESS REBOOT
PROBLEM
Board lo-
cation.
Interface
marker
INFO 0 = D-channel
51 CLOCK PROBLEM
Clock synchronization pro-
blem detected on an add-on
module interface
Board lo-
cation.
Access
marker
INFO 0 = type of interface: T0, T2,
DASS2, etc.
52 SPECIFIC ACCESS PRO-
BLEM DETECTED BY AN
ISDN BOARD LEVEL 2
Board lo-
cation.
Access
marker
INFO 0 = 1: FCS (Frame Check Se-
quence)
2: CRC (Cyclic Redundancy Check)
If the fault
recurs fre-
quently,
check the
connec-
tion to the
public
network.
TYPE MESSAGE LOCA-
TION
ADDITIONAL INFORMATION ACTION

Table of Contents