34 SOFTWARE KEY CHANGE CPU
board
(80)
INFO 0 = type of key (0= main key; 1
= CTI key)
INFO 1 = type of event
- 01: system booted with a key
which doesn’t correspond to the
system: the services are open for a
reduced period
- 02: system booted with a valid key
- 03: system booted with a key pro-
blem: the services are closed
- 12: valid key entered
- 13: the key present does not cor-
respond to the system: end of re-
duced period -> services closed
- 21: the key entered does not cor-
respond to the system -> services
open for a reduced period
- 32: the services are closed, valid
key entered -> services open
50 ISDN ACCESS REBOOT
PROBLEM
Board lo-
cation.
Interface
marker
INFO 0 = D-channel
51 CLOCK PROBLEM
Clock synchronization pro-
blem detected on an add-on
module interface
Board lo-
cation.
Access
marker
INFO 0 = type of interface: T0, T2,
DASS2, etc.
52 SPECIFIC ACCESS PRO-
BLEM DETECTED BY AN
ISDN BOARD LEVEL 2
Board lo-
cation.
Access
marker
INFO 0 = 1: FCS (Frame Check Se-
quence)
2: CRC (Cyclic Redundancy Check)
If the fault
recurs fre-
quently,
check the
connec-
tion to the
public
network.
TYPE MESSAGE LOCA-
TION
ADDITIONAL INFORMATION ACTION